Question
When I open Capture, I am receiving a message that says I have a script error. How can I correct this issue?
Answer
This type of error may be corrected by disabling the Start Page as follows.
- Open Capture and the session log.
Note: The Session Log is accessed from the menu: Window > Session log. The directory of the session log also includes the .ini file spinfo.ini. Note the path to this directory. - Open the spinfo.ini file in a text editor such as Notepad.
- Add the following lines to the file contents:
[Start Page]
EnableStartPage=false - Save the file and close Notepad.
- Open Capture. Capture should open without the scripting error.